How to properly reinforce brickwork?

In order for block walls with partitions to serve for a long time without deformation and destructive cracks, they must be erected in compliance with established rules, taking into account engineering calculations. Let's consider when it is necessary or not necessary to reinforce brickwork. Let's get acquainted with the options for the materials used and the features of the techniques used. Read to the end, and you will learn about strengthening structures with a thickness of ½ or ¼ brick.


Reinforcement of a masonry base with cladding using basalt mesh Source td-meaplast.ru

Selecting a grid for a specific width

Here they rely on the width of the wall that requires finishing.

Depending on the specific indicators in a particular case, the results will be as follows:

  1. When laying two and a half bricks and a width of 630 millimeters, a meter roll of mesh 50 by 50 by 2 is sufficient. Then it will be easier to cut the sheets to the required sizes.
  2. Masonry in two bricks, with a thickness of 500 mm. The mesh will also be 500 mm thick.
  3. One and a half bricks with a width of 380 mm. The mesh is purchased with a width of 500 millimeters. The partition is made from the pieces remaining after cutting.
  4. Single-brick masonry, with an indicator of 250 millimeters. The thickness of the mesh should be within the same limits.
  5. The masonry is half a brick with a width of 120 mm - then the mesh should have a thickness of 250 millimeters. It is simply cut in half.

Recommended reading:

How is reinforced brickwork made?

  • Principles of work
  • Brick wall: transverse type of reinforcement
  • Meshes for transverse reinforcement
  • Transverse type bar reinforcement
  • Longitudinal reinforcement
  • Summarizing

When constructing any structures, strength characteristics are the most important. Sometimes huge loads act on load-bearing masonry walls and columns, including brick ones. Requirements for the safe operation of such structures lead to the need to strengthen these structural elements. Reinforced brickwork is one of the common ways to increase the strength of buildings.

Types of bricklaying.

The technology of structural reinforcement has been developed over centuries. In particular, the question of how to reinforce brickwork was solved by our ancestors. The use of this technique is quite justified for critical structures that are subject to increased strength requirements. In general, reinforced masonry walls, although it complicates the design, fully fulfill its purpose.

Preparing for work

If you know how many rows to reinforce the brickwork, you can do all the work on reinforcing the walls yourself. For this you will need:

  • metal binding wire;
  • steel corner;
  • reinforcing mesh;
  • reinforcing bars;
  • rods made of round-rolled steel;
  • metal paint.

Reinforcement of brickwork: step-by-step instructions

Masonry mortar

Rules for strengthening the facade

In order to build the most reliable and durable walls, reinforcement of solid brickwork should be done from its very bottom. If the base is supposed to be assembled from brick, this procedure should be performed for it as well. Having laid the first row of bricks on the foundation strip, it is laid on top with ready-made reinforcement. In this way the first five rows are strengthened. Next, the wall is raised six rows in the usual manner and the reinforcement is laid again. Then the procedure is repeated.

Important: When assembling a brick pediment with a height of less than 8 m, the insertion is carried out - as in the construction of walls - every 6 rows. In the gable above every three rows are laid

Strengthening openings and problem areas

Very often cracks appear in the area of ​​openings. The fact is that quite serious tension arises in the masonry in this place. It can be compensated for by laying reinforcement. For a doorway, this operation is performed in two rows directly above it. Windows are also reinforced in two rows, but at the top and bottom.

Problem areas can also be areas where parts of a house of different heights adjoin. For example, where the project provides for the addition of a one-story extension to the main structure of two floors. Splits may appear at the joint due to differences in vertical pressure. In this case, the reinforcement of the brickwork is carried out in the last three rows of the low part of the masonry with its installation in the wall of a higher building so that the horizontal center of the mesh is located at the junction.

Masonry without bandaging seams

Sometimes the enclosing structures of buildings are laid out without bandaging the seams. Such houses look quite impressive and stylish. However, the masonry must be reinforced without fail. The grid is laid in every third row.

Advice: All of the above recommendations apply to Morfor fittings. If you are reinforcing with material from another manufacturer, you should first read the instructions for it. Installation rules for other fittings may be different. For example, a less reliable material can be used every 4 rows.

Rules for laying reinforcement

When reinforcing brickwork, it is worth observing certain standards. In this case, walls built with your own hands will be as reliable as possible. So:

  • The mesh is completely embedded in the solution.
  • If you are using ferrous metal fittings, they should be painted before installation.
  • The seams must be at least 4mm thicker than the rods.
  • When constructing a building, it is allowed to use only reinforcement of the same diameter and other parameters.
  • The mesh should have such a width that the ends of its elements protrude on one of the surfaces of the wall by a couple of millimeters.
  • If the mesh is made independently, its individual elements are connected with knitting wire. Welding is not recommended.

Sometimes owners of suburban areas have a question about how to make vertical reinforcement of brickwork. This procedure is usually performed only in seismically hazardous regions. The locations of the rods in this case are determined specifically for this particular project.

After how many rows is reinforcement carried out?

The frequency of horizontal laying of reinforcing mesh is determined by calculations based on building codes. The calculations take into account the load on the wall, the location relative to the axes and the height of the row. Reinforcement meshes are laid at intervals of 2-5 rows of ordinary brickwork. When using thickened bricks, reinforcement is carried out through 4 rows.

Zigzag laying is done in pairs in adjacent rows so that they are at an angle of 90° relative to each other.

The grids are located at a distance of no more than 45 cm from each other. When located greater than the specified distance, the effect of the reinforcement is reduced. When laying the mesh overlapping, the ends protrude at least 15 cm. The reinforcement bars extend onto the façade by at least 2 mm. This is done to control the correct installation and serves to firmly connect the exterior finish.

Reinforcement methods

In the technology of constructing load-bearing walls and internal partitions, reinforcement is laid in various planes in order to strengthen critical areas of the masonry of walls, columns, window and door openings, and arched ceilings.

Horizontal and vertical reinforcement of walls is used depending on the nature of the existing loads. Strong elements are laid into the rather fragile hardened mass of cement mortar along the entire length of the masonry. They evenly distribute local loads over the entire structure, preventing the appearance of cracks in places of stress.

Taking into account the possible directions of action of critical forces, reinforcement of brick walls is carried out in 2 planes:

  • transverse (deep into the seam);
  • longitudinal (along the surface or inside the masonry).

Additionally, longitudinal reinforcement is divided according to the method of orientation of the element relative to the surface of the walls into vertical and horizontal orientation.

In certain areas of the masonry, it is important to provide the correct reinforcement to maintain the integrity of the structure. Which method to choose in a particular case and how to place reinforcing belts in the walls, in how many rows to lay them, depends on taking into account in the project not only static weight loads, but also wind, snow, and seismic components

Which method to choose in a particular case and how to place reinforcing belts in the walls, in how many rows to lay them, depends on taking into account in the project not only static weight loads, but also wind, snow, and seismic components.

Compliance with the rules for the construction of walls and partitions refers to the creation of conditions for the safe operation of buildings and structures, ensuring the service life of individual housing construction is not lower than that calculated in the project.

The load-bearing capacity of a main wall or thinner partition can be increased by reinforcing the brickwork in the horizontal plane with metal mesh or tied wire. This method is also used to ensure the connection of the facing masonry with the backfill wall.

Building codes formulate the requirements for reinforcing brickwork with a mesh of horizontal joints:

Basalt reinforcing mesh allows you to reduce the amount of mortar due to the thickness of the seam. In addition, it does not require additional anti-corrosion coating and careful protection from the environment.

Easily cut to size using regular scissors. When choosing such a material, it should be taken into account that the ratio of the strength characteristics of steel and composite is 4:1, therefore, for the same loads, metal wire needs a smaller cross-section than basalt wire.

Industrially, the following options are made from steel rod according to standard cutting formats:

The best representative in its class for individual construction (where a large Ø rod is not required to provide increased strength) is expanded mesh for brickwork. It is produced in rolls, manually cut to the required size, has an anti-corrosion coating, and reduces the thickness of the seam compared to wire.

Mandatory rules

Reinforcement, carried out according to all the rules, allows you to increase the life of the building and evenly distribute the loads. Recommendations that must be followed:

  • the end of the reinforcing bar must be embedded in an adjacent stable structure;
  • if the load falls on one sign, then longitudinal single rods must be laid on the stretched side of the wall;
  • under alternating (positive or negative) loads, the rods are laid on the right and left;
  • all rods must have the same technical characteristics (length, diameter);
  • fixation of steps during strengthening is mandatory;
  • the diameter of the seam exceeds the diameter of the steel rod;
  • if internal reinforcement is carried out, the canvas is completely filled with concrete or cement;
  • reinforced belts connect height differences (attaching the constructed building to the part being built).

To strengthen a window opening, the reinforcing sheet must be laid in 2 rows (top and bottom of the opening), in a doorway - in 2 rows (lintels). Load-bearing walls are reinforced from below, the brick base is reinforced first.

General recommendations for reinforcement of brick structures

Strengthening brick pillars

There are two main types of brick pillars:

  • Performing the function of load-bearing columns. Supports are used to evenly distribute the load and support the floors placed on them. Such structural elements experience only vertical pressure.
  • Semi-decorative fence posts that can both connect sections of fencing and support gates and gates. Here the main type of load is horizontal.

Due to their small size, masonry reinforcement for pillars must be done using mesh or rods. The construction scheme for such pillars is as follows: the foundation, containing a reinforcement frame or a built-in metal pillar, is lined with brick. In this case, a reinforcing mesh is used in the horizontal section of the masonry. The construction of hollow columns with minimal strength is dangerous and impractical.

Facade reinforcement

It is possible to achieve the maximum effect from strengthening walls, making them more durable and reliable, only by making reinforcement from the very foundation. If the base of the building is brick, then its strengthening is also necessary. Reinforcement of the brick base begins after the first row is laid on the foundation. Reinforcing elements are laid out on top of it, the procedure is repeated in each of the next 5 rows. Subsequently, the wall is raised by another 6 layers of masonry, after which reinforcing rods are laid again. Next, the process is repeated cyclically.

Transverse

This type of brick wall reinforcement is characterized by the use of a mesh made of different materials and steel rods that protect the brick from deforming tensile and bending stresses. The rods are attached to the mesh using tying wire or welding. The rules establish the connecting pitch from 30 to 120 mm. Replacing the mesh with single reinforcement in a perpendicular plane does not comply with construction standards. For transverse reinforcement, a mesh with three main types of cells is used. It happens:

  • rectangular;
  • zigzag;
  • square.

The masonry is reinforced with a rectangular mesh with a diameter not exceeding 5 mm, and the cell size cannot be wider than 100 mm. Such a grid is laid through 5 rows of bricks. When performing work to strengthen the masonry, the reinforcing elements are positioned so that the edges of the reinforcement and mesh protrude somewhat beyond the front layer of brick. They will be deleted in the future.

Zigzag mesh for brickwork is made of wire with a diameter of 5 to 8 millimeters, the cell size ranges from 50 to 120 millimeters. It is laid in a horizontal plane every 2 layers of bricks and fastened with reinforcement located in adjacent rows at right angles.

Vertical

For this type of reinforcement, straight and zigzag mesh is used. Rods are laid between every 5 rows of bricks. The use of straight rods is recommended in row masonry of regular shape. The width of the reinforcing rods is arranged in increments of about 100 mm. The rods go deep into the mortar-filled joints to a depth of 20 mm.

Longitudinal

This type of wall strengthening, depending on the placement of reinforcing elements, is divided into internal and external. It is customary to reinforce brickwork in length with rods with a diameter of 10 millimeters or more. With internal strengthening, the reinforcement is placed along the walls, being recessed into the base of the masonry. For external installations, pillars attached to the wall are used to secure reinforcing elements. For small buildings, such as a private house, the thickness of the rods does not exceed 15 mm, while for large structures rods with a diameter of 30 mm and thicker are used. In the facing masonry, the spacing of the rods with a thickness of 120 mm must be observed.

With your own hands

In small volumes with a significant design thickness of the reinforcement, the mesh can be tied independently. It is not recommended to use conventional electric welding, as the rod loses its strength characteristics. In factory conditions, this operation is performed by automatic spot welding machines, which does not cause the metal to burn out.

The masonry is independently reinforced if the following materials are at hand, the quantity of which is determined by counting + a reserve of 10%:

  • knitting wire;
  • mesh (steel, basalt);
  • metal corner;
  • steel strip;
  • periodic fittings;
  • steel rods;
  • paint (for metal).

The need for materials of different Ø and profile is dictated by the fact that in the lower part (more loaded) the deforming forces are greater in all directions. Above the foundation, high resistance to bending (subsidence) is achieved by laying rods of at least Ø 8 mm along the surface of the wall. As the weight load decreases, horizontal and inclined impacts begin to predominate.

At the same time, the larger the Ø reinforcement, the greater the height of the mortar joint, which leads to a decrease in the strength of the brickwork itself. Therefore, in most cases, wire, strip or mesh with a thickness of 3 to 6 mm is used.

Mesh shape

In construction, reinforced brickwork of load-bearing walls, columns, and partitions is made from a mesh, which can have different cell shapes. The wire is welded together in the following arrangement:

  • square;
  • rectangle;
  • zigzag.

Zigzag reinforcing laying is carried out only during work on the construction site. It is made from wire rod from Ø 5 mm, the curvatures are made in increments of 5 – 10 cm. The cell size is taken from 3 to 10 cm, depending on the size of the rod with which we reinforce the structure.

Rectangular and square assemblies are made from wire 5 mm thick.

additional characteristics

The dimensions of the masonry nets must be selected before purchasing the product. The latter is made of highly bendable high-carbon steel. During the production process, the rods are coated with PVC or zinc for more impressive strength. A number of experts prefer galvanized mesh. However, recently, fiberglass coating options have become increasingly common, which give the product better quality characteristics. In the latter case, the mesh is lighter, its strength is increased, and the top layer protects against corrosion. If you want the reinforcement to last longer, you should use a product that is covered with fiberglass.

Technique for connecting façade bricks and main walls

Sometimes people build a house from one material and choose brick as the facing material. As a rule, the facade part is built first, and then the main walls are erected. Many people think that in this case there is no need to strengthen the masonry. This is a misconception, since any wall must be reinforced if you want it to last for a long time.

To reinforce the facing wall, use a mesh with a diameter of 4 mm. It is more practical to use than individual metal rods. With the help of welded mesh, you can finish the job faster and connect the façade and main walls without much difficulty. Alternatively, you can use regular wire or steel tape.

Those who do use wire will need to cut it into pieces of the required length. Most often this is done using a bolt cutter or a handy jigsaw. If you do not have such tools, then you can use ordinary pliers.

When the reinforcement is cut, you can begin laying it. To do this, you need to put it on a brick and press it down with another brick. After this, the mesh or wire must be connected to the backing masonry. It is better to carry out the construction of the main and facing masonry simultaneously, then you can adjust the height of the window sills to the same level. This will also help simplify the installation of lintels over door and window openings. During installation, you need to be extremely careful so that dirt does not get on the facing brick.

Even if you are sure that your house is in a safe place and will not be subject to any destructive forces, spend time reinforcing the walls. This part of the house bears the greatest loads, so they simply need to be strengthened. This will guarantee that your home will last a long time and will not require unplanned repairs.

Types and materials for manufacturing reinforcing mesh

All construction materials used to strengthen masonry are divided into two large categories:

  • light - with a cross-sectional diameter of less than 10 mm;
  • heavy - the thickness of which exceeds 10 mm.

At the same time, the technology for producing different types of reinforcing mesh varies: masonry, spot-welded, cold-rolled mesh reinforcement and others. Most often, masonry mesh less than 5 mm in diameter is used for transverse reinforcement. Also, the meshes vary in the material from which they are made; they are used:

  • steel;
  • basalt;
  • composite: glass and basalt plastic.

For example, basalt mesh is used to reinforce facing brickwork and wall masonry. Simultaneously with the strengthening of each of the masonry, they are fastened together. Composite meshes are approximately equal to basalt meshes in operational and consumer terms and are superior to metal ones both in technical characteristics and are more profitable from a financial point of view.

Types of execution

When constructing brick buildings, the following types of reinforcement are used to strengthen walls and partitions:

  1. Transverse. The brickwork is reinforced with mesh placed in horizontal joints. The following types of meshes are used:
    • factory-made galvanized metal masonry. They are produced in square, rectangular or zigzag shapes from hot-rolled smooth reinforcing steel A-I and BP-I with diameters of 3...8 mm with cells from 3 to 12 cm;
    • reinforcement bars connected with tying wire with a diameter of 5 to 8 mm. When using black rods, careful anti-corrosion painting is required;

  2. All-metal expanded metal mesh (CPVA) is a modern reinforcing product manufactured in a factory using expanded metal technology and having a specific gravity that is 2.5 times less than traditional welded mesh. The undoubted advantage is high strength, reliability and ease of installation;
  3. polyethylene and PVC mesh;
  4. composite and basalt. Products with low weight are not subject to corrosion and rotting, do not conduct electric current, and are characterized by high heat resistance and low thermal conductivity. The use of such products makes it possible to reduce the thickness of the seams due to the possibility of reducing the cross-section of the elements. This saves money.
  5. Nets are not laid in every row. How many rows the brickwork is reinforced is determined by the calculation set out in the building codes. In this case, the magnitude of the loads acting on the wall, their displacement from the central axes and the height of each row are taken into account. Most often, grids are laid at intervals of 2 to 5 rows, and when using thicker bricks, no more than 4. Zigzag ones are laid in two adjacent rows in pairs, so that the arrangement of the rods in them is mutually perpendicular.

    The effect of using meshes is reduced when they are located at a distance of ≥ 45 cm. Structurally, the products are located at intervals of ≤ 1 m. Installation is carried out with an overlap of ≥ 15 cm. The layer of mortar at the bottom and top should be ≥ 2 mm. The ends of the mesh should protrude from the inner surface by at least 2 - 3 mm. This makes their location accessible for visual verification of correct installation and serves to strengthen the connection with the internal lining. If necessary, the ends can be easily cut off with metal scissors.

    Reinforcement of masonry with nets is carried out in combination with a solution ≥ M 50.

  6. Longitudinal. Often used to reinforce brick partitions and main load-bearing walls to increase their flexural strength and resist lateral forces. A-I and A-II reinforcement with diameters up to 12 mm is used. It can be internal, for which purpose reinforcing bars (less often mesh) welded together with transverse reinforcement are placed in grooves made in the longitudinal seams in the mortar. Or externally, under a layer of cement mortar. The spacing of clamps for external reinforcement is taken to be ≤ 15 diameters of the reinforcement used, and for internal reinforcement 25 diameters. The strength of the walls directly depends on compliance with these conditions. Often, in non-load-bearing partitions made of half a brick, basalt mesh is laid in every 5th row. In the same way, reinforcement of facing brickwork can be carried out for connection with load-bearing walls.

    To strengthen thin partitions, steel corners connected to each other by metal bridges are also used to insert steel corners into the seams on both sides. Corners can be laid only on one side. Vertical rods or mesh are attached to the corners, followed by covering with plastering with cement mortar.

  7. Vertical reinforcement of brickwork. Often, brick columns are reinforced in this way, in which it is impossible to place reinforcement in the internal cavity or it is impossible to increase its size to perform external reinforcement. In this case, steel corners of the design cross-section are installed in the corners of the column or pillar, united by welding metal transverse bridges. This operation not only strengthens the masonry, but also partially absorbs the loads acting on the structure. For vertical reinforcement of walls, reinforcing bars are placed inside the voids in the brick and then filled with cement mortar. To do this, there must be voids in the masonry running through several rows.

    The diameters of rods of classes A-I, A-II, VI are usually taken from 10 to 16 mm, but in high-rise buildings it can increase to 30 mm or more. Vertical laying of reinforcement is especially necessary in areas with high seismic activity.

Description of methods

The choice of reinforcing material, cross-section and arrangement of materials in the body of the structure is regulated by building codes and regulations. However, their compliance is not enough to ensure that the masonry remains in good condition during the design period. It is also necessary to focus on practical recommendations that have been developed by technologists and tested by time. These include the following:

  • the rod elements and mesh for reinforcing the brickwork must be completely immersed in the masonry mortar;
  • the thickness of the seam between the bricks is formed taking into account an additional 4 mm to the reinforcement section;
  • when combining meshes and rod reinforcement on one object, samples with identical cross-sectional parameters and strength properties are selected;
  • individual rods made of ferrous metal are subject to mandatory treatment with an anti-corrosion compound and subsequent painting before installation;
  • to assemble mesh reinforcement from rods, it is permissible to use only galvanized steel binding wire (welding is excluded);


Knitting wire for reinforcement Source armamir.com.ru

About additional characteristics

The sizes can be thought through and selected before the purchase is made. The main production material is high-carbon steel, which bends well. To increase strength, during the production process the rods are coated with PVC or zinc. Then any masonry mesh, the cell sizes of which are selected individually, will last longer.

Many experts prefer to use the so-called galvanized mesh. But recently, fiberglass products have gained recognition in the market. In this case, performance really improves. Then the grid has the following advantages:

  1. Less weight.
  2. Increased strength.
  3. Top layer protected from corrosion.

Metal-plastic products guarantee maximum service life.

Why do builders prefer metal masonry mesh?

The undisputed leader in the field of reinforcement is still metal welded mesh. It has its advantages:

  • The mesh can withstand even significant loads perfectly. This is important if you plan to build several floors. Despite the heavy weight of the wall, the mesh does not deform and does not lose its qualities.
  • Rust resistance. This applies to fittings that have been properly treated against corrosion. Special compounds protect the rods from rust.
  • Metal mesh for reinforcement has a reasonable price. It is even more profitable to purchase it in wholesale quantities, when they can give a discount for a large volume.
  • Good selection of cell sizes. Thanks to the wide variety of meshes, you can choose exactly the option that suits your home. Most often, people buy nets with small cells.

Practical recommendations

The current SNiPs regulate the requirements for the performance of such work, which must be strictly observed:

the mesh is completely embedded in the mortar mixture; all metal elements are pre-painted to provide additional protection from corrosive formations; the thickness of the seam covering the reinforcing bars must be guaranteed to be exceeded; during construction work, the building is reinforced with one of the existing reinforcement options; choose a grid with the correct cell configuration; the edges of the mesh fabric should protrude from the masonry; to connect elements, use binding wire; the use of a welding unit is prohibited; reinforcement begins from the base of the structure, for which a frame made of reinforcement is laid on the first row of bricks laid on the foundation surface. After five rows the procedure is repeated; areas and openings that cause concern about the quality of operation are reinforced without fail

For example, a doorway is reinforced from above in two layers, and for a window block such a precaution is also provided from below; if the center of the structure is shifted, it is recommended to strengthen the upper contour of the lower edge of the object.

Often cracks appear around openings, because this is where the masonry experiences serious stresses, which are compensated by the laid reinforcement.

Problems are created by sections of walls of different heights adjacent to each other. The difference in vertical pressure contributes to the formation of splits at the joints. In such cases, it is recommended to carry out reinforcement on the last three masonry rows, placing reinforcement elements on higher walls in such a way that the central part of the mesh is laid horizontally at the joint.

Mandatory requirements

Regulatory documents for construction regulate the rules for performing work and requirements that must be observed. Let's look at them:

  • completely embed the mesh into the cement mortar;
  • paint metal elements before performing work, protect them from corrosion;
  • ensure that the thickness of the seam covering the rods is guaranteed to be exceeded;
  • use the same type of reinforcement when constructing a building;
  • pay attention to the configuration of the cells;
  • ensure that the mesh fabric protrudes beyond the edges of the walls;
  • use steel binding wire, do not use welding if the reinforcing products are made independently.

Some installation recommendations

The method of using the material is chosen individually by the master. According to the general set of rules, it would be better to use a grid at least every 5 rows. Three rows in the case of low-rise buildings.

Laying usually occurs as follows:

  • Flooring on the previous rows, forming an adhesion to the concrete.
  • The previous and subsequent rows are laid using the same technologies.
  • For the following rows, uniformity of the area is one of the important requirements. The concrete mixture covers the base completely.
  • 20 centimeters is the minimum thickness for overlapping mesh pieces.
  • 12 millimeters is the minimum thickness of mortar joints, where reinforcing mesh is added.

The need for a specific type of mesh for bricks at the present time is decided in advance. For example, in the case of a metal reinforcing belt, the thickness should be at least 2 millimeters.

The combination of the following components promotes the addition of individual masonry layers to each other:

  1. Concrete solution.
  2. Reinforcing mesh.
  3. Friction exerting a pressing effect.

Do not forget about the documents regulating such construction. SNiP recommends using the next belt after a certain number of rows. The cell size and other parameters are also strictly controlled.

It would be good to create the most detailed project; its absence in most cases only complicates the implementation. In most cases, the properties of meshes have long been tested in practice.

It is allowed to use different types of reinforcement on the same object. Thanks to the combination of their properties, the result is positive. Alternating the grid can be quickly resolved with proper calculations and drawings.

What is written in SNIP about this


The regulatory document regulating the construction of the reinforcing layer, namely SNiP 3.03.01-87 “Load-bearing and enclosing structures”, has the following points:

  1. When reinforcing masonry of external walls and columns, the thickness of the seam should be no more than 1.6 cm, and exceed the sum of the diameters of the reinforcement at the intersection by at least 4 mm. When laying transversely in walls and piers, the mesh must consist of at least two rods in width. And it should protrude beyond the outer edge of the wall by 2-3 mm.
  2. Partitions may not be reinforced if they are not secured with temporary fastenings, and have a height of 1.5 m and a thickness of 9 cm. With a thickness of 12 cm, the height should not exceed 1.8 m.
  3. With longitudinal steel reinforcement bars are connected by welding. If it is not used, then the rods end with hooks and are tied with wire. The rods overlap and each end should not be shorter than the sum of 20 diameters.

Calculations of the thickness, diameter and size of mesh cells are determined from the standards given in SNiP II-22-81 “Stone and reinforced masonry structures”.

For what purpose is it carried out?

During the shrinkage process, the walls do not become covered with cracks, and the load effects are removed from the masonry.

This work is performed in the following cases:

  • heavy loads are created on the enclosing structures of multi-storey buildings;
  • there is a possibility of cracks forming on objects built on weak soil compositions;
  • construction is being carried out in an earthquake-prone region, and increasing strength is necessary to counteract tremors;
  • when building arches from bricks or columns, carrying out complex masonry;
  • if low-quality building materials are used.